COMPARATIVE AMBIENT AND INDOOR PARTICULATE MATTER ANALYSIS OF OPERATION THEATRES OF GOVERNMENT AND PRIVATE (TRUST) HOSPITALS OF LAHORE, PAKISTAN

A. Nimra, Z. Ali, M. N. Khan, T. Gulshan, S. Sidra, J. R. Gardezi, M.R. Tarar, M. Saleem, Z. A. Nasir, I. Colbeck
1* 1 11, 2 3 4 45, 6 A. Nimra, Z. Ali, M. N. Khan, T. Gulshan, S. Sidra, J. R. Gardezi, M.R. Tarar, M. Saleem, Z. A. Nasir, I. Colbeck
1 Environmental Health & Wildlife, Department of Zoology, University of the Punjab, Lahore, Pakistan
2 Department of Wildlife and Ecology, University of Veterinary and Animal Sciences, Lahore, Pakistan
3 Services Institute of Medical Sciences, Lahore, Pakistan
4 Shalamar Medical & Dental College, Lahore, Pakistan
5 School of Energy, Environment and Agrifood, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK
6 School of Biological Sciences, University of Essex, Colchester, UK
Corresponding Author: zali.zool@pu.edu.pk
Page Number(s): 362-369
Published Online First: June 01, 2015
Publication Date: June 01, 2015

ABSTRACT

The link between infection and indoor air quality (IAQ) in operating theatres is well established. The level of airborne particulate matter (PM) in operating theatres in Pakistan has not yet been studied comprehensively. Monitoring of both indoor (operating theatre) and outdoor concentrations of PM in both activity and non-activity time periods was done using a DUSTTRAK Aerosol Monitor (TSI Model 8520) and DRX Aerosol Monitor (TSI Model 8533) for 24 hours. Two hospitals in Lahore were selected: Services Hospital (government – site 1) and Shalamar Hospital (private – site 2). The highest concentration of PM was observed in the orthopaedic operating theatre at site 1 during working hours with an average concentration of 757(±540), 809(±58), 824(±585), 875(±586) and 970(±581) µg/m3 of PM ,PM , PM , 1 2.5 4 3 PM and PM respectively while the average PM outdoor concentration was 294 µg/m . The minimum average PM 10 Total 2.5 concentration was found in the orthopaedic operating theatre at site 2 during working hours: 18(±8), 19(±8), 20(±9), 26(±9) and 39(±9) µg/m3 for PM , PM , PM , PM and PM respectively. The use of vertical laminar air flow 1 2.5 4 10 Total ventilation strategy was found to be an effective measure in reducing PM levels and it might be possible to predict the air quality of operating theatres by determining PM dust load. Factors such as ventilation system, door opening /closing rates, building age, possible sources of infiltration, number of people present in the operating area all play a role in influencing PM concentrations in operating theatres. greater air quality problems as compared to the rural
Keywords: Particulate matter, Operation theatre environment, IAQ in hospitals, Pakistan.
Open Access: This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( https://creativecommons.org/licenses/by/4.0/).


Download Statistics
This Manuscript
Full Text
7
downloads
Indicators
Metrics

Impact Score: 0.65; h Index:51

SJR: 0.20

Indexing
Status

Web of Science (SCIE): Q3

SCOPUS (Q3)

Journal Metrics
Current

Journal Impact Factor (JIF): 0.6; JCR 2026 ; Five Year JIF: 0.7

HEC Category: W

ISSN Details
Verified

Print ISSN: 1018-7081

Electronic ISSN: 2309-8694

Search the Journal

Use the fields below to search for articles by Title, Author, or Keywords.

All Downloads
Full Text
225,582
downloads
Supplementary
846
downloads