MONITORING OF PARTICULATE MATTER CONCENTRATIONS AT HIGH ALTITUDE ECOSYSTEMS OF PAKISTAN AND CHINA Authors: I. Zainab, Z. Ali, M. S. Ahmad, Z. Zona, S. T. Raza, S. Safdar, Z. A. Nasir, I. Colbeck, W. Liu Journal: Journal of Animal and Plant Sciences (JAPS) ISSN: 1018-7081 (Print), 2309-8694 (Online) Volume: 25 Issue: 3 Pages: 433-435 Year: 2015 DOI: NA URL: https://doi.org/NA Publisher: Pakistan Agricultural Scientists Forum Abstract: Particulate matter exhibits different behavior with altitude. A comparative analysis was carried out to monitor PM 1, PM , PM , PM and PM at elevations above 3000 m in both China and Pakistan. Real time monitoring of PM was 2.5 4 10 Total carried out at both sites using a DustTrak DRX (model 8533, TSI Inc.) for 24 hours each. In Pakistan, the average value of PM was 415 + 16 µg/m3 while in China the value was considerably lower i.e. 110 + 57 µg/m3. The 24-hour mean Total values recorded were well above the WHO recommended limit of 25 µg/m3. These results indicate that, even at sites some distance from anthropogenic sources, PM concentrations still pose a health risk. countries is major contributor for indoor air pollution due Keywords: NA